Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Tipo de estudo
Intervalo de ano
1.
Rev. Asoc. Odontol. Argent ; 111(3): 2-2, dic. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1550642

RESUMO

Resumen Objetivo Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para conectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos A partir de un modelo maestro que representa un maxilar desdentado con cuatro implantes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilladas al modelo maestro. Su desajuste inicial se analizó utilizando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un procedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructura metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significación fue establecido en p<0,05. Resultados El Grupo I tuvo un desajuste inicial de 97,30±13,81μm y el Grupo II de 98,53±11,24μm. Luego de la soldadura, el Grupo I registró 98,53±17,17μm, 1,23μm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61μm, 4,60μm por encima del original. Se analizaron mediante prueba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se observaron diferencias no significativas, p=0,41 y p=0,38 respectivamente. Conclusiones Bajo las condiciones de este estudio, se observó que los dos métodos de soldadura analizados fueron confiables para unir supraestructurasos metálicas sin que se afecte su ajuste final.


Abstract Aim Compare two conventional welding procedures using a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master model. Its initial mismatch was analyzed using a stereoscopic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statistically. The level of significance was established at p<0.05. Results Group I had an initial mismatch of 97.30 ±13.81μm, and Group II of 98.53±11.24μm. After welding, Group I registered 98.53±17.17μm, 1.23μm higher than the initial one. In Group II, 103.13±17.61μm was observed, 4.60μm above the original. They were analyzed using Student's t test; in both cases the result was p>0.05. When comparing groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions Under the conditions of this study, it was observed that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit.

2.
Acta odontol. latinoam ; 28(3): 203-209, 2015. ilus, graf
Artigo em Inglês | LILACS | ID: biblio-949696

RESUMO

Improperly treated hexavalent chromium-containing industrial wastes contaminate drinking water, potentially affecting children taking breast milk or baby bottles prepared with infant formula. Thus, the aim of the present work was to determine the effect of this toxic on bone activity in the developing alveolus during tooth eruption of suckling Wistar rats intoxicated with potassium dichromate. Experimental animals received a daily dose of 12.5mg/kg body weight of potassium dichromate by gavage for 10 days; controls received an equivalent volume of saline solution. Histologic and histomorphometric studies of the mandible were performed. The data were statistically analyzed using Student's t test; statistical significance was set at a value of p <0.05. Experimental animals exhibited delayed tooth eruption, decreased periodontal width and bone volume, a lower percentage of bone formation surfaces, and higher percentage of quiescent surfaces (p<0.05) compared to controls. The delay in tooth eruption observed after exposure to hexavalent chromium is the result of a lower rate of bone remodeling in the developing alveolus. The obtained results show the importance of controlling toxic substances in drinking water, since their effects may alter the growth and development of subjects who were exposed during early infancy.


Desechos industriales que contienen cromo hexavalente inade - cua damente tratados contaminan el agua de consumo pudiendo afectar a los ninos por via de la leche materna o de la preparacion de mamaderas. Por lo tanto, el objetivo del presente trabajo fue determinar el efecto de este toxico en la actividad del hueso en el alveolo en desarrollo durante la erupcion dentaria de ratas Wistar lactantes expuestas a dicromato de potasio. Los animales experimentales recibieron una dosis diaria de 12,5 mg / kg de peso corporal de dicromato de potasio por alimentacion forzada durante 10 dias; mientras que los controles, un volumen equivalente de solucion salina. Se llevaron a cabo estudios histologicos e histomorfometricos de la mandibula. Los datos fueron analizados estadisticamente utilizando la prueba t de Student; estableciendose un valor de p<0,05 como esta - disticamente significativo. Los animales expuestos a cromo hexavalente mostraron retraso en la erupcion dentaria, menor espacio periodontal y volumen oseo; encontrandose disminuidas las superficies en formacion y en reabsorcion oseas y aumentadas las superficies en reposo (p <0,05) en comparacion con los controles. El retraso en la erupcion dentaria observado luego de la exposicion a cromo hexavalente es el resultado de una menor remodelacion osea en el alveolo en desarrollo. Los resultados obtenidos muestran la importancia del control de sustancias toxicas en el agua potable, ya que sus efectos pueden alterar el crecimiento y el desarrollo de los individuos que fueron expuestos durante la infancia temprana.


Assuntos
Animais , Ratos , Erupção Dentária , Desenvolvimento Ósseo , Peso Corporal , Ratos Wistar , Mandíbula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA